Edge Ultrasound System Guida Utente Pagina 58

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 57
46 Measurements
3 Press the SELECT key.
A second caliper appears.
4 Using the touchpad, position the second caliper
at the end diastole on the waveform.
See “To save a measurement to a calculation
and patient report” on page 43.
To measure time duration (Doppler)
1 On a Doppler spectral trace, press the CALIPER
key.
2 Press Time on-screen.
A vertical caliper appears.
3 Using the touchpad, position the caliper where
desired, and press the
SELECT key.
A second caliper appears.
4 Using the touchpad, position the second caliper
where desired, and press the
SELECT key.
To trace manually (Doppler)
1 On a frozen Doppler spectral trace, press the
CALIPER key.
2 Select Manual on-screen.
A single caliper appears.
3 Using the touchpad, position the caliper at the
beginning of the desired waveform, and press
the
SELECT key.
If calipers are not positioned correctly, the result
is inaccurate.
4 Using the touchpad, trace the waveform.
To make a correction, select Undo on-screen,
backtrack with the touchpad, or press the
BACKSPACE key.
5 Press the
SET key.
The measurement results appear.
See “To save a measurement to a calculation
and patient report” on page 43.
To trace automatically (Doppler)
After tracing automatically, confirm that the
system-generated boundary is correct. If you are
not satisfied with the trace, obtain a high-quality
Doppler spectral trace image, or trace manually.
(See “To trace manually (Doppler)” on
page 46.)
1 On a frozen Doppler spectral trace, press the
CALIPER key.
2 Select Auto on-screen.
A vertical caliper appears.
3 Using the touchpad, position the caliper at the
beginning of the waveform.
If calipers are not positioned correctly, the
calculation result is inaccurate.
4 Press the
SELECT key.
A second vertical caliper appears.
5 Using the touchpad, position the second caliper
at the end of the waveform.
6 Press the
SET key.
The measurement results appear.
See “To save a measurement to a calculation
and patient report” on page 43.
Automatic trace results
Depending on the exam type, the results from
automatic tracing include the following:
Velocity Time Integral (VTI)
Peak Velocity (Vmax)
Mean Pressure Gradient (PGmean)
Mean Velocity on Peak Trace (Vmean)
Pressure Gradient (PGmax)
Cardiac Output (CO)
Peak Systolic Velocity (PSV)
Time Average Mean (TAM)*
+/× or Systolic/Diastolic (S/D)
Vedere la pagina 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 197 198

Commenti su questo manuale